LP and HP tapping purge of Fractionator bottom LT

Home Forums Coking LP and HP tapping purge of Fractionator bottom LT

Viewing 1 reply thread
  • Author
    Posts
    • #1635
      Freddy Martinez
      Participant

      Dear friends,
       
      In one of the newly constructing coker plant, fractionator bottom LT purges on both LT and HP tapping are given with HCGO. I have seen only FG purge on LP tapping and FLO on HP tapping in my previous coker.. But this is new for me. Can anyone help me how this purge is possible and how it works.
       
      Thanks in advance

    • #4437
      Anonymous
      Inactive

      HCGO purge for LT is not a better option as HCGO CCR content is normally 1.3 wt% FLO and FG can be used based on the process conditions

Viewing 1 reply thread