Wash Oil Flow Quantuty

Home Forums Coking Technical Fractionation & Process Process Wash Oil Flow Quantuty

Viewing 2 reply threads
  • Author
    Posts
    • #2313
      Freddy Martinez
      Participant

      My Plant had some trouble related CHGO CCR wt%
      I had shut down plant & find problem.
      that reason is fouling of #1~4 Tray
      I think wash oil is so little, that make dry tray & fouling.
      so I have to decide How much wash oil is reasonable.
      Is there any criteria or calculation tool ? It there are that tools or criteria, would you let me know.

    • #5149

      coker fractionator with tray in the wash zone and P1 tray below wash section, bring this problem (old design) this area should always keep a lower temperature to 730 F; loss of flow or low flow in this section like you say are going to coke up from the wash zone to the shed tray section, a rule can be maintain a minimum flow of 3 to 4 gpm per inch of weir

      the other method is that you can simulate this section (program simulation) and calculate the flow such that at least 30% of the flow remains liquid (leaving the plate P1), because once that tray are dry and again to get wet again the HCGO vaporizes and begins to coke up

      Best Regrads

    • #5145
      Claus Graf
      Participant

      You might find this article helpful:
       
      http://www.fwc.com/publications/tech_papers/files/HP09%20OptimizeCokerOps.pdf
       
      Regards
       