      In our coke drums which will be commissioned ,the side feed entry facility available in view of delta valves and alternate drain/quench facility is not given.
      Kindly share your valuable feed back regarding water draining and quenching , is any problems arrived ?
       
      Regards & thanks
      Ashok Singh  

    • #4945
      Anonymous
      Inactive

      i dont have delta valve

    • #4944
      Rodney Reeves
      Participant

      We have Delta Valves on our Coker with side feed lines entering the drums.  It is a new coker at only four years old, but we have had no problems quenching or draining (no transfer line plugging).

    • #4897
      Anonymous
      Inactive

      we have coke drum with delta valvaes side feed entry in coke derum bottom.some time we faced problem in water quaching . feed line presssure goes high more than 8.5 kg on that time we line up alternate line