      Hi,
      We are plannibg to replace cokedrum with 1 ft large diameter.
      26 t0 27 ft . Can you help to know what are the minimum  jet water pressure required to cut coke bed effectively / or is thereany typical thumbrule for cokedrum dia. vs coke cutting water pressure?

    • #5907
      Claus Graf
      Participant

      Well, it depends……
       
      What kind of coke are you making ?
      What is your current cutting water pressure ?
      What is your current water flow ?
      How fast do you want to cut the coke ?
      What cycles are you running ? 24, 18 hr ?
      Do you plan on running shorter cycles with the larger drums ?
      What cutting tool do you currently have ?
      How efficient is your current cutting operation ?
       
      Regards,
       
      CG

    • #5906
      Anonymous
      Inactive

      Ask the question to the vendors (Flowserve, Ruhurpumpem).Thet will naswer in no time.

    • #5901
      Anonymous
      Inactive

      some designer take like thumb rule between 110-130 psig for each feet of drum diameter (fuel grade)

    • #5772
      Anonymous
      Inactive

      125 psi/ft diameter seems to be at least one rule of thumb that I keep running into.  I read this in some literature on Norm Lieberman and other places.