Blowdown vent gas compressors

Home Forums Coking Technical Fractionation & Process Process Blowdown vent gas compressors

Viewing 4 reply threads
  • Author
    Posts
    • #3347
      Anonymous
      Guest

      Anybody using vent gas compressors (i.e. screw type) to recover the bolwdown gas and send it to the suction of the WG compressors?. I heard that you may also use ejectors instead of rotating equipment. Any reliability issues?.
      Thanks, R.I.

    • #6480
      Anonymous
      Inactive

      Depend if the pressure in the blowdown is 5 psig higher than the suction pressure you can used the wet gas compressor 

    • #6479
      Claus Graf
      Participant

      Reliance is recovering gases normally sent to flare from the blowdown system with ejectors. See document in the link below.
       
      Regards,
       
      CG

    • #6435
      Anonymous
      Inactive

      yes,  since 2006,  been operating 2 screw compressors on the flare system and sending them back to the gas plant

    • #6183
      Lucibar Davalillo
      Participant

      Is there any other coker, besides Reliance Jamnagar in India, using ejectors to recover coke drum vents to blowdown?
       
      What’s the lowest pressure can get at coke drum before venting to atm., after quench, without using ejectors at blowdown?
       
        

Viewing 4 reply threads