Six (6) Drum Coker

Viewing 2 reply threads
  • Author
    Posts
    • #3807
      cokerdragon
      Participant

      Greeting
         Anyone working at a (6) six drum Coker? if so I would like some infor if you don’t mind

      1. What size drums do you have
      2. What rates are you running
      3. what is your cycle and what type of Coke are you making
      4. What COT’s do you run and what is your max feed rate
      5. Do you run sludge and what/how many tons a week or mins per sludge injection cycle.
    • #6796
      Anonymous
      Inactive

      I work in 8 drum Coker each of size 8 meter dia and 37 meter height…
      We are running at 163000 BPD rate
      15 hr cycle… Fuel grade coke
      COT – 496 deg celcius and pass flow is 86-88 m3/hr
      Sludge injection cycle is 30-45 mins

    • #6611
      Anonymous
      Inactive

      I know of 6 drum cokers that run on a single fractionator on 12 hr cyles with rates of close to 110,000b/d.   The question that is important is to understand if the 6 or 8 drum cokers are on one fractionator or 2.  The six drum cokers I mention are making shot coke.  They all have new unheading systems with the DeltaValve valve on top and bottom of drum

Viewing 2 reply threads
  • You must be logged in to reply to this topic.
2923 Topics 3878 Replies

Coking forum

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Curabitur aliquam venenatis venenatis. Vestibulum tempus malesuada rhoncus.

Open forum